Foamsulate Closed Cell

Medium Density

Foamsulate Closed Cell is a two-component, medium density, one to one by volume spray applied polyurethane foam. To produce Foamsulate Closed Cell requires the use of an “A” component (ISO) and a blended “B” component (RESIN) which contains ZERO ozone depleting blowing agents, catalysts, polyols and fire retarding materials. Foamsulate Closed Cell is an insulation system designed for use in residential, commercial and industrial applications. Use in lieu of more traditional forms of insulating materials such as fiberglass, cellulose or other loose fill products.

Typical areas where spray polyurethane foam is applied are:

EXTERIOR WALLS • VENTED ATTICS • UN-VENTED ATTIC ASSEMBLIES • BETWEEN FLOORS • FOUNDATIONS CRAWLSPACES • HVAC DUCTS • FLUID TANKS • COLD STORAGE UNITS

Typical Physical Properties
Property FOAMSULATE Closed Cell TEST
R-VALUE 6.9 @ 1" ASTM C 518
CORE DENSITY 2.0 LB / Cubic Foot ASTM D 1622
CLOSED CELL CONTENT > 90% ASTM D 6226
SOUND TRANSMISSION COEFFECIENT 41 ASTM E 90-85/E 413
WATER VAPOR TRANSMISSION -
PERMEANCE
0.8 Perms at 1”
0.23 Perms at 3.5”
ASTM E 96
AIR IMPERMEABLE < 0.005 (L/s-m2) ASTM E 2178
NOISE REDUCTION COEFFICIENT 0.10 ASTM C 423
TENSILE STRENGTH (PSI) 58 psi ASTM D 1623
DIMENSIONAL STABILITY < .27% ASTM D 2126
COMPRESSIVE STRENGTH (PSI) 41 psi ASTM D 1621
BUILDING CODE CERTIFICATIONS / FIRE TEST DATA
EVALUATION SERVICE REPORT IAPMO UES 352
BUILDING TYPES Approved I, II, III, IV, V-B: Nonstructural Insulating Material
FLAME SPREAD ASTM E84 Class I < 10
SMOKE DEVELOPMENT ASTM E84 Class I < 195
ASTM C 1029 Spray Applied Polyurethane Thermal Insulation Meets or Exceeds Type II
ASTM E 119 Pass Non Load-Bearing - 1 Hour Rated - Wall Assembly
NFPA 259 Potential Heat 1883 Btu/ft2 Per Inch Of Thickness
NFPA 285 Pass Compliant For Use In Building Types: I, II, III, IV, V
UL LISTING FWFX.R38039 Exterior Wall System Components
UL LISTING FWFO.EWS0013 System No. EWS0013 Exterior Wall Systems
NFPA 286 Pass: Can be used without a code prescribed 15-minute thermal barrier when covered with one of the approved intumescent coatings as shown on page 2.
NFPA 286
AC377 APPENDIX X
Pass: Complies with the applicable requirements of ICC-ES AC377 Appendix X for use in attics and crawlspaces without a prescriptive ignition barrier.
UL 1715 Pass: Can be used without a Code prescribed 15-minute thermal barrier when included as a component in tested alternative thermal barrier assemblies.
FLORIDA BUILDING CODE FL 17185: FL Building Code 2010: RULE 61G20-3: Approved for use as supplemental attachment of roof OSB deck to rafters/truss top chords (dimensional lumber) for commercial and residential buildings. Product may be used for Code-plus wind resistance in new construction or enhancing the wind uplift resistance on existing structures.