Foamsulate HFO 2.0
High Density
Foamsulate HFO 2.0 is a two-component, next generation HFO blown medium density spray applied polyurethane foam. The HFO technology allows Foamsulate HFO 2.0 to be produced with a Global Warming Potential (GWP) of less than One and with an Ozone Depletion Potential (ODP) of Zero. To produce Foamsulate HFO 2.0 requires the use of an “A” component (ISO) and a blended “B” component (RESIN) which contains ZERO ozone depleting blowing agents, catalysts, polyols and fire retarding materials. Foamsulate HFO 2.0 is an insulation system designed for use in commercial and residential applications. Use in lieu of more traditional forms of insulating materials such as fiberglass, cellulose or other loose fill products.
Typical areas where spray polyurethane foam is applied are:
EXTERIOR WALLS • VENTED ATTICS • UNVENTED ATTICS ASSEMBLIES • BETWEEN FLOORS • FOUNDATIONS • CRAWL SPACES • HVAC DUCTS • FLUID TANKS • COLD STORAGE UNITS
Typical Physical Properties
Property | FOAMSULATE HFO | TEST |
---|---|---|
R-VALUE | 7.2 @ 1" 25 @ 3.5" |
ASTM C 518 |
CORE DENSITY | 2.0 LB / Cubic Foot | ASTM D 1622 |
CLOSED CELL CONTENT | > 90% | ASTM D 2856 |
Building Code Certifications / Fire Test Data
BUILDING CODE CERTIFICATIONS / FIRE TEST DATA | ||
---|---|---|
EVALUATION SERVICE REPORT | IAPMO | UES 650 |
FLAME SPREAD | ASTM E84 | Class I < 25 |
SMOKE DEVELOPMENT | ASTM E84 | Class I < 450 |
NFPA 286 | Pass: Pass: Can be used without a Code prescribed 15-minute thermal barrier when covered with one of the approved intumescent coatings as shown on page 2. | |
NFPA 286 AC377 APPENDIX X |
Pass: Pass: Complies with the applicable requirements of ICC-ES AC377 Appendix X for use in attics and crawlspaces without a prescriptive ignition barrier. |