Foamsulate 50
Light Density
Foamsulate 50 is a two component, light density, one to one by volume spray applied polyurethane foam. To produce Foamsulate 50 requires the use of an “A” component (ISO) and a blended “B” component (RESIN), which contains ZERO ozone depleting blowing agents, catalysts, polyols and fire retarding materials. Foamsulate 50 is an insulation system designed for use in residential, commercial and industrial applications. Use in lieu of more traditional forms of insulating materials such as fiberglass, cellulose or other loose fill products.
Typical area’s where spray polyurethane foam is applied are:
EXTERIOR WALLS • INTERIOR WALLS • VENTED ATTICS • UN-VENTED ATTIC ASSEMBLIES • BETWEEN FLOORS • CEILINGS
Typical Physical Properties
Property | Foamsulate 50 | Test |
---|---|---|
R-VALUE | 3.7 @ 1" | ASTM C 518 |
CORE DENSITY | 0.5 LB / Cubic Foot | ASTM D 1622 |
OPEN CELL CONTENT | > 97% | ASTM D 6226 |
SOUND TRANSMISSION COEFFECIENT | 42 | ASTM E 90 |
WATER VAPOR TRANSMISSION - PERMEANCE | 21 Perms at 1” | ASTM E 96 |
AIR IMPERMEABLE | < 0.02 (L/s-m2) | ASTM E 283 |
NOISE REDUCTION COEFFICIENT | 0.10 | ASTM C 423 |
TENSILE STRENGTH (PSI) | 5.19 psi | ASTM D 1623 |
DIMENSIONAL STABILITY | < 5% | ASTM D 2126 |
BUILDING CODE CERTIFICATIONS / FIRE TEST DATA | ||
---|---|---|
EVALUATION SERVICE REPORT | Intertech UVA IAPMO |
ESR 3081 UES 0351 |
EVALUATION SERVICE REPORT | ICC - FBC Supplement | Florida Building Code - Building Florida Building Code - Residential |
BUILDING TYPES | Approved | I, II, III, IV, V-B: Nonstructural Insulation material |
FLAME SPREAD | ASTM E84 | Class I < 20 |
SMOKE DEVELOPMENT | ASTM E84 | Class I < 400 |
NFPA 259 | Pass: Standard fire test method for evaluation of fire propagation characteristics of exterior non-load bearing wall assemblies containing combustible components. | |
NFPA 285 | Pass: Standard fire test method for evaluation of fire propagation characteristics of exterior non-load bearing wall assemblies containing combustible components. | |
NFPA 286 | Pass: Can be used without a 15-minute thermal barrier when covered with one of the approved intumescent coatings as shown on page 2. | |
NFPA 286 AC377 APPENDIX X | Pass: Complies with the applicable requirements of ICC-ES AC377 Appendix X for use in attics and crawlspaces when covered with one of the approved intumescent coatings as shown on page 2 of the Technical Data Sheet. | |
UL LISTING | FWFX.R38039 | Exterior Wall System Components |
UL LISTING | FWFO.EWS0013 | Exterior Wall Systems |